Buscar
Mostrando ítems 1-10 de 299
In vitro biomechanical evaluation of sagittal split osteotomy fixation with a specifically designed miniplate
(2013-03-01)
Recent studies have evaluated many methods of internal fixation for sagittal split ramus osteotomy (SSRO), aiming to increase stability of the bone segments while minimizing condylar displacement. The purpose of this study ...
In vitro biomechanical evaluation of sagittal split osteotomy fixation with a specifically designed miniplate
(2013-03-01)
Recent studies have evaluated many methods of internal fixation for sagittal split ramus osteotomy (SSRO), aiming to increase stability of the bone segments while minimizing condylar displacement. The purpose of this study ...
Comparison of five different fixation techniques of sagittal split ramus osteotomy using three-dimensional finite elements analysis
(Churchill LivingstoneEdinburghEscócia, 2012)
An In Vitro Evaluation of Rigid Internal Fixation Techniques for Sagittal Split Ramus Osteotomies: Setback Surgery
(W B Saunders Co-Elsevier IncPhiladelphia, 2012)
Fixation of autogenous bone grafts with ethyl-cyanoacrylate glue or titanium screws in the calvaria of rabbits
(Churchill Livingstone, 2009-02-01)
This study compared the fixation of autogenous onlay bone grafts with cyanoacrylate glue (Super Bonder) and with titanium screws. Twenty rabbits underwent bilateral parietal ostectomies. Bone segments were fixed anteriorly ...
Fixation of autogenous bone grafts with ethyl-cyanoacrylate glue or titanium screws in the calvaria of rabbits
(Churchill Livingstone, 2009-02-01)
This study compared the fixation of autogenous onlay bone grafts with cyanoacrylate glue (Super Bonder) and with titanium screws. Twenty rabbits underwent bilateral parietal ostectomies. Bone segments were fixed anteriorly ...
Effect of the number of screws on the stability of locking mandibular reconstruction plates
(2013-03-25)
Atrophic mandible fractures are frequently a challenge to stabilize. This study evaluated, through mechanical testing in vitro, the number of locking screws that is sufficient to withstand loading when applied with a locking ...
Effect of the number of screws on the stability of locking mandibular reconstruction plates
(2013-03-25)
Atrophic mandible fractures are frequently a challenge to stabilize. This study evaluated, through mechanical testing in vitro, the number of locking screws that is sufficient to withstand loading when applied with a locking ...
THE PHOTOELASTIC ANALISYS OF VERTEBRAL FIXATION SYSTEM SCREWS
(ATHA COMUNICACAO & EDITORA, 2009)
Introduction: The photoelasticity is used for assessing the tensions/deformations involved in photoelastic materials when submitted to a given load by the observation of optical effects. The screw performance and mechanical ...